csd_comet_header_de.jpg - 39606 Bytes
English

Data logger for current 0-20mA,
voltage 0-5V and binary signal

Data Logger

Data logger S6021, respective S5021

Data loggers are designed for record of voltage signal 0-5V (optionally 0-10V) or current signal 0-20mA. At the same time state of binary signal can be recorded. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper adapter.

Main applications of data logger:

Advantages of data logger:

  • included traceable calibration certificate from the manufacturer - Comet
  • fast data transfer to the PC (full memory for approximately 30s)
  • variability of connection to the computer - USB, RS232, Ethernet, GSM modem
  • permanent connection to the PC enabled, data is possible to download even during logging
  • large data memory 32000 values
  • large dual line display with special symbols, switchable
  • optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
  • dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display
  • two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is cleared)
  • robust watertight case
  • easy installation, locking enabled
  • low power consumption from battery, battery life up to 6 years
  • indication of remaining battery life, easy replacement of the battery
  • logging start/stop is enabled: at certain time and date programmed from computer, by external binary signal or by delivered magnet
  • also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm limits
  • input signal is recalculated and displayed in real measured physical units by means of the PC software
  • each logger is possible to describe with text of maximum 32 characters
  • each channel is possible to describe with text of maximum 16 characters
  • password protection is enabled to prevent unauthorized manipulation with logger
TECHNICAL PARAMETERS
Measurement accuracy: ±0.2% FS
Resolution of voltage input: 13 bits (8192 levels)
Resolution of current input: 7900 levels
Signal character at binary input: from potential-less contact or two-state voltage signal
Minimum pulse duration at binary input: 500 ms (shorter pulses may not be recorded)
Maximum frequency at binary input: 0.5 Hz (i.e. maximum 5 pulses for 10 s)
Power current through contact at binary input: 3 uA (contact closed)
Voltage accross open contact at binary input: maximum 3.6 V
Low voltage level at binary input: 0 to +0.2 V (maximum current from the input 3 uA
High voltage level at binary input: +3.0 to +30 V (maximum current to the input 100 nA
Data logging interval: adjustable from 10s to 24hours
Display refresh and alarm state refresh: every 10 s
Total memory capacity: 32000 values (in non cyclic mode)
Data logging modes: noncyclic – logging stops after filling the memory
cyclic – after filling memory oldest data is overwritten by new
Operation temperature range: -30 to +70°C
Real time clock: year, leap year, month, day, hour, minute, second
Built-in connector for input signals: Canon 9 pins, male
Dimensions without connectors: 93x64x29mm
Weight including battery: 130g
Power: Lithium battery 3,6V, size AA
Typical battery life in operation from -5 to +35°C:
(if often operated outside of the above temperature range battery life can be reduced to 75%)
6 years
Battery life in continuous on-line mode with interval 1 minute: 4 years
Battery life in continuous on-line mode with interval 10 seconds: 1 year
Protection: IP67 - protected against influence of temporary immersion into water
Warranty: 2 years
DATA LOGGER TYPES
Types of data loggerMeasuring rangeManual of data logger in pdf format
Larger photo of data logger S5011 - single channel voltage data logger 0-5Vdc + binary signal
(0-10Vdc available as an option)
Manual of data logger in pdf format
Larger photo of data logger S5021 - dual channel voltage data logger. Input channels are not galvanic isolated and have common ground. 0-5Vdc + binary signal
(0-10Vdc available as an option)
Manual of data logger in pdf format
Larger photo of data logger S6011 - single channel current data logger. The current loop should be powered from external power supply. 0-20mA + binary signal Manual of data logger in pdf format
Larger photo of data logger S6021 - dual channel current data logger. The current loops should be powered from external power supply. Input channels are not galvanic isolated and have common ground. 0-20mA + binary signal Manual of data logger in pdf

Manual of data logger in pdf Common manual for quick start of the loggers

Accessories

Traceable calibration certificate from the manufacturer, instruction manual. Calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Example of calibration certificate.

No other accessory is included. For basic use it is necessary to order at minimum a COM adapter or USB adapter for communication with computer, optionally a start/stop magnet, if needed to control logging the other way than directly from computer or by external binary signal. Also connector for input signals connection is necessary to order.

Anytime it is possible to download free basic Windows program for data logger. Program enables to control all logger functions and viewing and printing of record in numerical and simple graphic format. It is possible to export recorded values to dbf or txt formats for further analysis.

OPTIONAL ACCESSORIES
Image of data logger program SWR004 Windows optional software for data logger - color printing, vertical and horizontal zooming of graphs and other functions.
Database Logger Program DBL Database program DBL Logger Program for work with data from Comet loggers.

Program enables i.a.:
- To set locally the GSM modem via RS232 link by means of the QMS2901 cable.
- To view selected channels from any Comet logger together with selected channels of other Comet loggers.
- Measurement from different Comet devices is possible to combine in one table or graph.
- To choose any time interval for analysis.
- Print, export to PDF - table and graph.
- uses freeware database server MySQL
Larger photo of data logger CD SW100 CD with free PC program
Larger photo of data logger adapter LP002 COM adapter for communication with personal computer via RS232 serial port
Larger photo of data logger adapter LP003 USB adapter for communication with personal computer via USB port
Larger photo of data logger adapter LP005 LAN adapter - external converter for communication with the PC via Ethernet, including ac/dc adapter 230Vac/5Vdc.
Exceeding of adjusted limits is alarmed by sending e-mail message or trap.
More information in manual of Ethernet interface in pdf Manual of data logger LAN adapter in pdf
GSM data logger

New !

Wireless communication with loggers via GSM
Larger photo of data logger magnet LP004 start/stop magnet
Larger photo of data logger Dual Lock MD036 self adhesive Dual Lock for easy installation
Larger photo of data logger holder F9000 wall holder secured against unauthorized removal
Larger photo of data logger battery A4203 spare Lithium battery 3.6V size AA
Larger photo of data logger connector K0921 watertight female connector Canon 9 pins for connection of input signals, protection IP67.
Larger photo of data logger connector K0925 female connector Canon 9 pins for connection of input signals, protection IP20.
Larger photo of data logger adapter K0945 Adapter with terminals for easy connection of input signals, protection IP20. Adapter enables to supply connected transducers e.g. from ac/dc adapter connected via power connector.
More information in manual of adapter in pdf Manual of data logger adapter in pdf